Skip to end of metadata
Go to start of metadata

Description

Version 1.9.3 for Ignition platform 7.9.3 


Click on the link to download this release!!

The Production Module will be installed automatically by any of the SPC, OEE, T&T and RM modules. Instrument Interface, Web Services and the Barcode Scanner module do not require the Production Module to be installed.

Change Notes

OEE Module

Change_TypeChange Logrev
Fixed

Added "SequenceDate" to join on PROD_Cell_Summary table from PROD_Line_Summary table. When recording the shift change the timestamps are the same so we can get data from the wrong shift included.

full
Fixed

Removed "eventBeforeShiftChanged" when determining if an active downtime event crosses a shift change. This causes issues in that the next shift record is not updated. OEEDTLine:updateDownTime()

full 
Fixed

Cell calculations to trigger the same as in line. OEEDTCell.execute(). Line does not calculate on shift change, cell was so that the before and after shift recordings were not the same values.

full 
Added

Index to PROD_Run_Summary for RunUUID + Line. RunRecorder:verifyTableSchemas()

full
  • No labels