Skip to end of metadata
Go to start of metadata

Overview

You use the Value Editor and find Equipment State, at the Line level, with strange negative value(s) that you know!, are not 
in any of your Equipment State(s) ...


Applies To and Version Info

2.0

Details

The MES modules use -2147483648 (-2^31, the minimum value for a 32-bit integer) to mark downtime events that have been split.
We just use that value because it's a value no one would ever use or can ever use

Notes

The 4 cases for not splitting are

  1. it is still an ongoing Event
  2. the Event is only 1 second long
  3. The selected base Equipment is not a Line  MES Selector (Equipment Path property for the OEE DTT is pointing to Cell Group or Cell)
  4. It is already a split Event

References

OEE Downtime Table

system.mes.oee.splitEquipmentStateValue

Keywords

downtime, event, split

OEE

Configuration, Run-control-and-Monitoring: Adjusting-OEE-Run-values Production-data.




  • No labels