Overview

The MES Analysis Selector and MES Analysis Controller components both have a Filter By section that is typically set to the equipment path. Instead of settling for a static string value for the equipment path that must be changed manually (e.g. to run analysis on a different Line), you can create a Custom Property in the component to use as an equipment path variable. This variable can now be modified on the fly via script or by binding it to the Equipment Item Path property of an MES Object Selector.

Applies To and Version Info

This feature applies to the OEE 2.0 module.



Create a Custom Property

  1. In either the MES Analysis Selector and MES Analysis Controller component, create a Custom Property to hold the equipment path string, such as "eqPath".

  2. When used during run time, you can either modify the equipment path string held in this property via script or by binding it to the Equipment Item Path property of an MES Object Selector.









Keywords

OEE

OEE, MES Analysis Selector, Row Limit, Descending Order