Skip to end of metadata
Go to start of metadata

Overview

These are the Data Points and Settings that can be used in an Impromptu Analysis (Selector or Controller)
to produce results matching the OEE Downtime Table

Applies To and Version Info

2.0

Details

DataPoints=Line State Event Begin,Line State Event End,Line State Duration,Is Short Stop,Short Stop Threshold,
Line Downtime Equipment Path,Line Downtime Original Equipment Path,Line Downtime Equipment Name,
Line Downtime Reason,Line Downtime Reason Path,Equipment Note,Line State Value,Line Downtime State Time Stamp,
Line Downtime End State Time Stamp,Line Downtime Reason Split,Line Downtime Can Revert Split,Line Downtime Event Sequence,
Line Downtime Occurrence Count,Line State Override Type,Line State Override Scope,Line State Overridden

Filter=Equipment Path=@eqPath AND (Line State Type='Planned Downtime' OR Line State Type='Unplanned Downtime' OR Line State Type='Unknown')

GroupBy=Line Downtime Event Sequence

OrderBy=Line Downtime Event Sequence

SettingValues=Rollup Time Span=0,Suppress Grouping Messages=True,Unknown State as Unplanned Downtime=False

note:

1) eqPath would be a Custom Property on the Analysis Selector

2) The Settings values can be matched in the OEE Downtime Table by setting the Properties

Screenshots

Impromptu 

OEE Downtime Table

you can use this code to create this Analysis (you will have to close/open your Window with Impromptu to get this loaded back)

analysis_setting = system.mes.analysis.createMESAnalysisSettings("Like OEE DT Table")

Datapoints = [
			"Line State Event Begin",
			"Line State Event End",
			"Line State Duration",
			"Is Short Stop",
			"Short Stop Threshold",
			"Line Downtime Equipment Path",
			"Line Downtime Original Equipment Path",
			"Line Downtime Equipment Name",
			"Line Downtime Reason",
			"Line Downtime Reason Path",
			"Equipment Note",
			"Line State Value",
			"Line Downtime State Time Stamp",
			"Line Downtime End State Time Stamp",
			"Line Downtime Reason Split",
			"Line Downtime Can Revert Split",
			"Line Downtime Event Sequence",
			"Line Downtime Occurrence Count",
			"Line State Override Type",
			"Line State Override Scope",
			"Line State Overridden"
            ]
analysis_setting.setDataPoints(Datapoints)

analysis_setting.addParameter('eqPath')
analysis_setting.setFilterExpression("Equipment Path=@eqPath AND (Line State Type='Planned Downtime' OR Line State Type='Unplanned Downtime' OR Line State Type='Unknown')")
analysis_setting.setGroupBy("Line Downtime Event Sequence")
analysis_setting.setOrderBy("Line Downtime Event Sequence")
analysis_setting.setSettingValues("Rollup Time Span=0,Suppress Grouping Messages=True,Unknown State as Unplanned Downtime=False")

system.mes.saveMESObject(analysis_setting)


References

MES Analysis Selector
MES Analysis Controller
Analysis Data Points and Settings

OEE Downtime Table

Keywords

OEE Downtime Table, Analysis Controller, Analysis Selector, Analysis Data Points and Settings

OEE

Configuration, Analysis-and-reports, Production-data.



  • No labels